The run-time gauge

How long does it run in an hour?

Time it on a hot afternoon and put the figure in. The gauge says what that run time is telling you about sizing, airflow and whether the house is being dried out at all.

The gauge

Pick a genuinely hot afternoon — the hottest part of the day, doors shut, nothing unusual going on. Watch the outdoor unit for an hour and add up the minutes it actually runs. That single number tells you more about a system than any other thing you can measure without tools.

Run-time gauge A circular gauge whose filled portion shows the minutes per hour selected below. The same figure and the same conclusion are written out beside the gauge. 25 minutes per hour
Is the house holding the temperature you set?

What that run time means

Very short cycles — this is the clammy-house pattern

Running only a few minutes at a time means the coil barely gets cold before the thermostat is satisfied. The temperature comes down; the moisture does not. On this coast that is the difference between a house that feels cool and a house that feels cold and damp at the same time.

  • Check the filter and the return first. Restricted airflow shortens cycles and is the cheapest thing to rule out.
  • Check the thermostat is not in a draught, in sunlight, or above a supply register.
  • If those are fine, the system is very likely larger than the house needs. That cannot be repaired — it is fixed at replacement, with a load calculation.
  • A variable-speed or two-stage system is the usual answer where oversizing is confirmed, because it can run long and slow.

Run time depends on how hot it is outside, what the house is doing and where the thermostat sits, so one reading on one afternoon is an indication rather than a diagnosis. Time it over two or three hot days before drawing conclusions, and never use it on a mild day — short cycles in mild weather are normal for any system.

Plainly

What the gauge cannot do

  • It does not measure humidityIt infers a problem from cycle length. A cheap hygrometer in the room is a better direct measure and worth owning on this coast.
  • It does not size anythingWhere a system turns out to be oversized, the replacement is sized from a load calculation — not by going one size down from what is there.
  • It is not a reason to raise the setpoint and hopeIf the house is losing temperature with the system running flat out, something is wrong and it will not fix itself.